Those who operate machinery should be most annoyed by this situation. When the equipment is in use, it will go on strike, which not only delays the progress but also fears equipment damage. Purified water equipment often encounters downtime. What should be done when storing water in a pure water tank?
1、 Short term shutdown
The purified water equipment system software will be shut down for 5 days to January in the short term, during which time the RO membrane components are still installed in the RO reverse osmosis system software. It is necessary to clear the vapor safety in the system software, and then clean the system software with tap water. Pay attention to the probability of closing the gate valve to avoid steam entering after filling the system software with water, and clean it every 5 days to ensure smooth operation of the equipment again.
2、 Long term shutdown
1. Clean the membrane components in the system software.
2. Use RO reverse osmosis to produce water and prepare disinfectant, and use the disinfectant to clean the RO reverse osmosis system software. The use of pesticide fungicides and the preparation method of disinfectant can refer to the relative technical documents of the membrane enterprise or contact the local office of the membrane enterprise to obtain relevant technical proposals.
3. After filling the RO reverse osmosis system software with disinfectant, close the relevant gate valves to save the disinfectant in the system software. At this time, it should be checked that the system software is completely filled; Shenyang Anti Osmosis Principle.
If the temperature of the system software is less than 27 ℃, the first two processes should be carried out with new disinfectant every 30 days. If the temperature of the system software is higher than 27 ℃, the maintenance solution (disinfectant) should be replaced every 15 days.
Before the RO reverse osmosis system software is delivered for use again, clean the system software with bottom pressure water supply for 1 hour, and then use high-pressure water supply to clean the system software for 5-10 minutes. Regardless of whether bottom pressure cleaning or high-pressure cleaning is carried out, the water discharge valve of the system software should be fully opened. During the process of restoring the system to normal operation, it is necessary to check and verify that the product water does not contain any pesticides or fungicides.
RO reverse osmosis composite membrane components should not come into contact with water containing residual chlorine under all conditions, otherwise it will cause irreparable damage to the membrane components. When carrying out sterilization, chemical properties, or sealing in maintenance fluid on RO equipment and pipelines, it should be absolutely ensured that there is no residual chlorine in the water used for preparing the medicine. If it is not clear whether there is residual chlorine present, organic chemistry measurements should be carried out. When residual chlorine is present, sodium bisulfite should be used to restore the residual chlorine and maintain a good contact time to ensure thorough restoration.