What are the effects of high pressure in purified water EDI equipment- Pure Water Equipment - Jiajie - Jiajie Pure Water Equipment Manufacturer


The purified water EDI equipment is composed of RO reverse osmosis system software and EDI system, both of which require pressurization in order to work. Both systems have certain pressure requirements, especially for the RO reverse osmosis system software and machinery equipment. The pressure should not be too high or too high, otherwise it will pose a serious threat to the mechanical equipment. So, what are the problems caused by the high pressure of the relevant purified water EDI equipment?

The purified water EDI equipment generally needs to ensure a pressure of 0.2-0.5MPa in the middle, directly because it allows the regeneration characteristics to be fully utilized to achieve good practical results; The pressure is less than 0.5MPa in order to better ensure the actual effect of salt absorption.

1. When the pressure is too high, perform reverse cleaning. If the hole of the upper spray nozzle is very large, the expansion water of the epoxy resin adhesive is relatively large, which can easily cause the epoxy resin adhesive to enter the multi way valve from the top, leading to serious leakage of the epoxy resin adhesive.

2. Discovering abnormalities in the shut-off valve can lead to unstable water indicators. When the pressure is too high, an incalculable pressure may be caused on one side of the multi way valve, and it is also highly likely to occur on the microporous plate. During the operation of the shut-off valve, it is very likely that it will not be smooth, and it may also cause the shut-off valve to not immediately turn on and off the power supply, resulting in the water quality not reaching the expected actual effect.

3. When the pressure is too high, it is necessary to introduce salt water again. At this time, a lot of water must be introduced into the salt tank. The high water level line may also cause water outflow.

4. When the pressure of the purified water EDI equipment is too high, the salt absorption effect will become faster and faster, reducing the regeneration time and cannot guarantee the actual effect of regeneration.