The key function of industrial softened water equipment is to reduce the intensity of source water, and with the continuous improvement of consumer application regulations, this key component has been improved. At present, the automation technology level of industrial softened water equipment is high, the product specifications are diversified, and the application is more convenient and fast, which can meet different requirements. But if the actual operation is not stopped during the entire application process, it will immediately endanger the quality of the water output. If the salt absorption of the machine equipment is blocked, how should I solve it?
If industrial softened water equipment fails to absorb salt or absorbs salt slowly during operation, the first step is to identify the cause of this situation and then carry out targeted maintenance to solve it. The reasons for the obstruction of salt absorption in the reconstruction include: low working pressure of water supply and drainage, blockage of physiological saline filtration device pipeline, blockage of salt absorption pipeline, and blockage of water injector. During inspection, we can follow the following order:
1. Check the air pressure gauge at the water inlet to determine if the seepage working pressure meets the basic specifications.
2. Check if there are prefabricated components in the salt suction pipe.
3. Twist the physiological saline filtration device apart and clean it with clean water. If the problem persists, the lock cover at the upper end of the water injector must be removed and cleaned thoroughly.