The long-term stable operation of industrial ultra pure water equipment is related to the operation and management of equipment in our daily lives. Therefore, when using industrial equipment, it is necessary to strictly operate the equipment according to the requirements. Here are your management methods for sharing the operation of industrial pure water equipment:
Sharing of Operation Management Measures
1. Strictly control the water quality of the equipment, ensure that the water quality meets the equipment requirements, and prevent damage to membrane components in industrial equipment.
2. Control the working pressure of the equipment: Under the premise of meeting the production volume and water quality, lower pressure values are adopted to better prevent the problem of decreased membrane water flux and reduce the frequency of membrane replacement.
3. Temperature control of solution entering the equipment: During this period, using a temperature that does not meet the requirements for water production and quality as the inlet temperature can effectively reduce the attenuation of membrane water volume.
4. Emission control: When the water temperature and pressure remain constant, the water output of the equipment can also change accordingly. At this point, it is necessary to adjust the equipment emissions to prevent any impact on the desalination rate of the equipment.
5. Summer high temperature solution:
(1) Maintain the inlet water volume of industrial ultra pure water equipment to meet the requirements and reduce the operating pressure of the equipment.
(2) According to the water demand, if multiple industrial equipment are used in rotation, the downtime of the equipment should not exceed 24 hours to prevent bacterial growth in the membrane components and affect the water production efficiency.
6. The downtime of the equipment should not be too long. If a shutdown is required for at least 72 hours, a protective solution should be used to prevent the growth of bacteria inside the equipment.
When the equipment stops or just starts, the inlet water pressure should be adjusted to below 0.4MPa and rinsed for 15 minutes.
8. The equipment needs to record operating data every two hours, such as:
Inflow: pH value, conductivity, pressure, SDI, water temperature.
Water production: conductivity, flow rate, pH value.
Concentrated water: flow rate, pressure. And the inlet pressure of each part.
9. Equipment operators need to undergo training to avoid equipment operation errors and damage.
The above is the operation and management method of the industrial ultra pure water equipment that you shared, hoping to be helpful to you. The operation management of the equipment is relatively strict, providing a guarantee for the stable operation of the equipment.