During the use of reverse osmosis equipment, it is inevitable to encounter some problems, which can lead to the normal start-up of the equipment. Next, let's discuss some of the reasons why it cannot start.
1. The pressure switch is not set correctly.
The pressure switch plays an irreplaceable role in the normal operation of the system, maintaining the water supply pressure of the equipment host and maintaining the normal operation of the relevant pumps. However, it is common for the host to fail to start due to settings errors.
2. AC contactor failure.
There are many situations where the main water pump cannot start due to damage to the AC contactor. For example, if the AC contactor of the raw water pump malfunctions and cannot automatically engage, the rear system will also be unable to function. This solution is relatively simple, just replace it with a new one.
3. The liquid level controller is damaged or improperly placed.
The liquid level controller is an important control component in the reverse osmosis device. Once the equipment does not start, the following liquid level controllers of the raw water tank and pure water tank should be checked for any malfunctions.
4. The water pump cannot be started or is damaged.
Press the AC contactor directly into the electrical control box, then manually pull it in. If the water pump can rotate, the fault of the water pump can be ruled out.
Reverse osmosis equipment is a common water treatment equipment that cannot be separated from the filter during operation. So, what are common filter cans?
Mechanical equipment filters and multi material filters: Foot operated filters are a type of working pressure filter that can be used as pre-treatment system software for river water or drinking water sources. Multi material filters can remove small colloidal solution particles and suspended solids, and control the corrosiveness of water to be above 1 degree or below.
Iron removal equipment manganese removal machine: mainly uses water to fully contact with carbon dioxide, achieving the actual effect of air oxidation of iron and manganese in water to produce colloidal precipitation.
Activated carbon filter: capable of removing organic matter, colloidal solution particles, microbial strains, residual chlorine, odor, etc. from water. According to the selected particle activated carbon or synthetic pore adsorbent, adsorbent carbon, etc., activated carbon filters are widely used, with good dissolution effect, reliable operation, convenient management methods, and recyclable adsorbent.
Spiral wound filter tank: a softener that can achieve precision filtration and high efficiency. According to the requirements of tap water, different precision reverse osmosis equipment can be selected to filter the winding. And can complete automatic operation, maintain continuous water output, standardized modular design, control system design, customers can equip according to their needs, strong interchangeability.